Floor Drain Sizing Calculator

Size floor drains per UPC/IPC requirements

Drainage Area

Flow Parameters

Equipment discharge, hose bibs, etc.

Drain Requirements

Minimum Drain Size --
Per-Drain Capacity --
Total Drainage Area --
Design Flow Rate --
Drain Fixture Units --
Max Distance to Drain --
Code Note: Floor drains must have trap primer or trap seal maintenance device per UPC/IPC.

Floor Drain Capacities

Drain Size DFU Rating Max GPM Max Area (sf)
2"212200
3"427400
4"850800
6"161001,600
8"321753,000

Floor Drain Requirements by Application

Restrooms

3" minimum

1 per 400 sf

Trap primer required

Commercial Kitchen

4" typical

1 per 200 sf

Grease interceptor

Industrial

4"-6" typical

Based on flow

May need acid resistant

Parking

4"-8" typical

1 per 500-1000 sf

Oil/sand interceptor

Installation Requirements

Floor Slope

  • 1/8" per ft minimum
  • 1/4" per ft typical
  • Max 25 ft to drain
  • 2% max for ADA

Trap Protection

  • Trap primer connection
  • Trap seal primer device
  • Deep seal trap (4"+)
  • Weekly maintenance option

Strainer/Grate

  • ADA compliant pattern
  • 1/4" max openings
  • Heel-proof for walking
  • Heavy duty for traffic